Model: MCP9700A
Measurement range: [-40ºC ,+125ºC]
Output voltage: (0°C)500mV
Sensitivity: 10mV/ºC
Accuracy: ±2ºC (range 0ºC ~ +70ºC), ±4ºC (range -40 ~ +125ºC)
Supply voltage: 2.3 ~ 5.5V
Response time: 1.65 seconds (63% response from +30 to +125°C).
Typical consumption: 6μA
Maximum consumption: 12μA