===== Energy Storage and Distribution ===== ==== Overview ==== At the core of the renewable energy plant is an all-in-one proprietary unit, the ZBB EnerStore, which allows the plant to operate "off-grid". This system performs the following major functions * Input rectification or conversion of the varying renewable sources. * Battery storage of power for later use * AC Output Inverter The output is then fed onto a separate building micro-grid, using standard 3 Phase 415VAC voltage, that is connected to certain devices and powerpoints placed throughout the building that are solely powered by the renewable energy generated. ==== ZBB EnerStore ==== A promotional video describing the system from the manufacturer is [[https://www.youtube.com/watch?v=yCvvFS5bYLo|available here]] and for an explanation of how the flow-cell technology works see [[https://www.youtube.com/watch?v=W4HoiRgXjSI|this video]]. === Flow Battery Specifications === * Zinc-Bromide (Zn-Br2) flow battery technology. * Ionic charge is stored in ZnB solution * High cycle life. 1000's of full discharge/recharge cycles with no loss of performance. * Capacity: 2x 50kWh Flow Batteries (100kWh total) * Maximum charging rate: 17kW * Maximum discharging rate: 25kW * 70% Round-trip efficiency at the DC point of connection (inclusive of all auxiliary power loads). === Inverter Specifications === * Max Continuous Output Power: 25kW * Max Continuous Output Current: 69A ==== Micro-Grid ==== The building microgrid is fed directly from the ZBB EnerStore output AC inverter to a Main Distribution Board. It outputs power to the following devices and locations via sub-distribution boards: * Basement Electric Car Charging Outlets (not yet implemented) * Deans Winter Garden Grow Lights * Level 9 Common Room * Labs on level 6, 10 ==== Downloads ==== * {{:technical:renewables:ac-pcu_25kva_specifications.pdf|Inverter Specs}} * {{:technical:renewables:30-000361_50v31c_manual.pdf|Enerstore (Battery) Manual}} * {{:technical:renewables:flow_battery_schematic.pdf|Flow Battery Electrolyte Circuit}} * {{:technical:renewables:flow_battery_chemical_process.pdf|Flow Battery Electrical Process}} * {{:technical:renewables:zbb_electrolyte_msds.pdf|ZBB Electrolyte MSDS}} * {{:technical:renewables:hazards_register.pdf|Hazards Register}} * {{:technical:renewables:znb_barrels_storage.doc|Zinc Bromide Storage Risk Assessment}} * {{:technical:renewables:znb_storage_swms.doc|Zinc Bromide Storage SWMS}} * {{:technical:renewables:znb_barrels_removal_from_site.doc|Zinc Bromide Movement Risk Assessment}} * {{:technical:renewables:znb_removal_swms.doc|Zinc Bromide Movement SWMS}} * {{:technical:renewables:zinc_bromide.pdf|Zinc Bromide Safety Handbook}} * {{:pecc_control.pdf|CON3 Control Schematic}} ==== Links ==== * [[http://www.zbbenergy.com/products/flow-battery/zess-50/|ZBB EnerStore Website]]